- Bachelor of Science in Electrical Engineering/Computer Science or equivalent experience preferred.
- Minimum of 4 years’ experience in control systems and startup/commissioning.
- Experience with pipeline and/or oil and gas processing a plus.
- Must have experience with low and medium voltage controls.
- Must be able to clearly and effectively communicate in English via verbal and written methods and be comfortable and effective doing so directly to customers and co-workers.
Controls Equipment to be used include:
- Allen Bradley ControlLogix / CompactLogix / PLC5 / SLC500 / FactoryTalk / RSView (PLC/HMI)
- GE RX3i / RX7i / 90-30 / 90-70 / QuickPanel / iFIX / Cimplicity / Proficy (PLC/HMI)
- Siemens S7-300 / S7-400 / S5 / TI / WinCC / WinCCFlex / TIA (PLC/HMI)
- Schneider (SquareD) Modicon Quantum / ClearSCADA / (PLC/HMI)
- DeltaV (DCS)
- Wonderware InTouch / ArchestrA / System Platform / Win911 (HMI)
- OPC Systems SCADA (HMI)
Industry experience:
Oil and Gas, Utilities, Agriculture, Metals, Mining, Paper, Data Centers, Health Care
Requirements:
- Must be able to lift up to 50 pounds, climb ladders, stand for extended periods, drive regularly, with or without reasonable accommodations
- Should be able to pass a fit for duty physical exam when required
- Must be able to pass a pre-employment drug test and periodic, unannounced random drug tests.
- Must be able to pass a pre-employment criminal background check.
- All offers are conditioned on acceptable results from a background check and drug and alcohol screening.
- Must have a valid driver’s license, and currently have and be able to maintain a good driving record.
- Must be eligible to work in the U.S. without need for employer-sponsored visa (work permit).
- Must be able to fluently read, write, and speak English.
- Must be willing to travel up to 75%.
Preferred experience:
- MicroSCADA (we use Ver 10.6)
- Configuration using iec670
- HMI screen building
- IEC61850 protocol and engineering (MMS & GOOSE)
- IET670 for Hitachi relays
- SEL Architect for SEL relays
- Networking concepts
- PRP protocol
- VLANS
- Communication Protocols
- DNP3
- IEC104
- Modbus
- SNMP
- Ethernet switch programming (Hitachi AFS & Hirschmann)
- Firewall programming concepts
- Power system protection concepts
- Able to read schematics and single line diagrams
- Troubleshooting concepts
- Wireshark
- Hitachi ITT670
- Hitachi RTU programming & testing
- rtuTil software
- RTU560 RTUs
EQUAL OPPORTUNITY EMPLOYER | DRUG-FREE WORKPLACE
Shermco is an Equal Opportunity Employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, age, disability, or veteran status. Shermco is a drug-free workplace.
NO AGENCIES PLEASE